Techne Calibration Tecal 140S and Tecal 140H temperature calibrators NEW THREE YEAR WARRANTY
Tecal 140S and Tecal 140H
This range of temperature calibrators is ideal for calibrating temperature sensors used in the food and pharmaceutical industries in addition to calibrating any sensors used in the temperature range outlined in the specifications below.
S Version: Set required Temperature and Calibrate
H Version: Set required Temperature and Calibrate; also programmable for switch test and ramp rate etc.
Tecal 140S
The Tecal 140S provides a complete system for calibrating most types of thermal sensors used in the temperature range of -40°C to 140°C which includes K type thermocouples commonly used in the food industries, cold storage rooms and environmental monitoring systems.
Tecal 140H
Where automation in both the field and laboratory are required, the combination of the Tecal 140H with the UPI saves time and money. The user can set the program and leave the unit to calibrate the probes, automatically storing the results in memory. This allows the user to attend to other tasks and when convenient download the results to a computer to print the calibration certificate.
Using advanced peltier technology and state-of-the-art mechanical and electrical components, these calibrators can rapidly cover the complete temperature range where speed is of the essence without loss of accuracy or stability. The heater block with a defined measuring zone of 50mm from the bottom of the block allows for different length/active area sensors.
Although the improved accuracy and stability is ±0.2°C & ±0.05°C respectively, one can often achieve an accuracy of ±0.1°C and a stability of ±0.02°C with high class RTDs and thermocouples.
Technical Specification- Note Improved accuracy specification
Specifications Tecal 140S & H
Temperature range 45°C below ambient to 140°C (typically -20°C in an ambient of 25°C)
Temperature range with CH-5 unit -40°C to 140°C (using Chilled water supply through heatsinks)
Display Accuracy ±0.2°C
Temperature Uniformity ±0.2°C
Measuring zone 0 to 50mm from base of well
Temperature Stability ±0.05°C ( after 10 mins)
Display resolution 0.1°C or 0.1 °F
Display units selec table °C or °F
PC Interface RS-232
Heating rate 20°C to 100°C 5 minutes
Cooling rate 100°C to 0°C 9 minutes
Ramp Rate °C per min 0.1 to 10 on H version
Switch test on H model
Large well Ø:38mm x 135 mm deep lnserts
Fan Cooling Automatic
Additional Cooling Water Cooling channels on S and H models
Carry case Soft carry case included
Dimensions L x W x H (mm) 285 x 190 x 426
Options
• Wide range of inserts and custom options available
• Techneworks software and cable (on S model) supplied with H model
• Hard Carry case
• UKAS calibration certificate